11 RC-100BZ Heat Pump 2 Stage Heat / 1 Stage Cool Thermostat Installation Instructions DESCRIPTION The RC-100BZ is a precision digital thermostat d
1100 11 Cooling minimum on/off time (minutes) This item is used to limit the on and off times of the cooling system. When the cooling system starts
1111 15 Filter reminder The thermostat logs the amount of time the system fan has been running. When this setting reaches 0, the thermostat will dis
1122 QUICK-REFERENCE SETUP GUIDE This table displays each Installer Setup item with its default setting. The column labeled "CURRENT" can
1133 The thermostat supports the following command classes: COMMAND_CLASS_THERMOSTAT_MODE COMMAND_CLASS_THERMOSTAT_SETPOINT COMMAND_CLASS_THERMOSTAT_
1144 COMMAND_CLASS_THERMOSTAT_OPERATING_STATE Upon power up, allow 10 seconds for the RC-100BZ thermostat to initialize. After 10 seconds, a control
1155 TROUBLESHOOTING TIPS SYMPTOM ACTION TO TAKE 1. Check power to the thermostat 2. Check wiring diagrams Thermostat Dead 3. Check thermost
1166 HEAT PUMP CROSS REFERENCE GUIDE RC-100BZ R (1) G (2) O (3) B (4) C (5) Y (6) W2 (7) X2 CARRIER, PAYNE DAY&NIGHT R G O C Y1 W2 L TRANE R
22 Removing an existing thermostat 1. Disconnect the power to the control transformer. 2. Remove the cover to the existing thermostat. 3. Disconne
33 Connect each wire to the terminal strip on the thermostat base per the wiring diagram for your system application - See Figures 4 - 5. Form the
44 TYPICAL WIRING DIAGRAMS CAUTION: Be sure to disconnect the power to the control transformer before removing or installing thermostat. Do not sho
55 Figure 5
66 CONFIGURING THE BACKLIGHT ON THE RC-100BZ The backlight on the RC-100BZ can be configured to one of three different modes: 1) on for 30 seconds wh
77 POWER UP 1. Double check wiring, be sure that there are no stray wires or wire strands at the connections. 2. Connect power to the transformer
88 00 Address If you are using Communications Mode 0 or 1, and you are installing more than one thermostat, each must be set to a consecutive addr
99 03 Display options The thermostat can be configured to display the following attributes: 0 Celsius am/pm time format programmable 1 Fahre